The information contained in this post is for general information purposes only. The information is provided by pool timer trippers not working and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the post for any purpose.

Paul, it could be that you got a 50hz motor, instead of a 60hz? Still no luck. One morning I noticed my pool didnt automatically turn off. Wired correctly, #10 wire, nothing. Is that a faulty motor? It is an ON tripper right? Inspect the tripper portion, if it looks rounder or worn, replace them. Is it Necessary? Ive seen it happen from lightning strikes, or insect infestation. I have the same issue currently, and it makes no sense to me so far. You most likely just need to now set the pins and the clock and your timer will work. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Timer not tripping pump on. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. Just installed a new timer. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Reset the clock on the timer to the correct time to get it back to the desired on/off times. The green tripper is a recent thing - maybe the last 3 years they have been included in the replacement bag. 1100 Juanita St, Austin, TX 78704 | MLS #6354744 | Zillow Ive got the opposite problem than a lot of people. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). TORK Repair Questions & Solutions, Tips & Guides - Fixya The other gears move very slowly, and appear to not move at all, except for one I believe? Is it toast ? And Ive noticed lately that the ON is not functioning all the time. I bought a new timer and replace the T104 timer clock. Is it possible to do this by loosening the timer screw a bit? If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. My intermatic timer is not turning my pool pump on. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. I just replaced an Intermatic WG1573-10D timer motor. Things are working fine and all of a sudden the pool pump did not start in the morning. Can breaker be bad? "name": "In The Swim",
Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. Reset the clock to the correct time. There is power; gears are moving. What Causes Problems With Intermatic Timers? - Reference.com But no gears or any sound. March 16, 2022 by WildRiverCountry. Can I wire this timer to an outlet or should I search for another solution? Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Back when I was a young technician I was taught to always look for the easy things and use all my senses. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. Still no luck. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. I believe its the manual on/off switch that is the problem. You will want to make sure the manual switch under the timer wheel is pushed to the on position. Theres an issue with the wiring between the circuit breaker and the timer. Or may be bent and not come together. 120Volt Tork 1101 timers can be fixed with repair parts. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. How Does My Pool Timer Work? | eHow You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Welcome to Pool Spa Outpost! The power should run from the breaker, to the timer, to the pump. Some white lithium grease on the switch can help in some cases. "url": "https://intheswim.com/",
If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. Pool timer malfunction - DoItYourself.com Community Forums Ill do the same. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Intermatic T100 Series Replacement Trippers for Timers 156T1978A - The #1. My Tork TU40 pool pump timer wont turn on the pump. The red - JustAnswer Hello, newer pool guy here. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. Pool Timer Parts - Pool and Spa PartsFinder | In The Swim 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting Then turn the breaker, that the time clock is connected to, off and back on again. Hi, new timer out of the box, 200V. Advice? Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts The timer appears to be working fine (keeps time). Watch these tips and tricks before replacing it. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. After a power failure the timer clock can start up backwards, mine has done this several times. How about the GFCI outlet TEST button, is it tripped? I unscrewed the clip and put it back on and its still doing the same thing. Now ever sense I did that last week my timer wont shut off or turn on my pool pump. Does this mean I need a new T104, or is there a replacement manual on/off switch? },
I have a inground pool with T10003RT4 control panel. Intermatic Pool Timer Troubleshooting & Repair Guide - WeT HeaD Media Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. The on/off pins are tight and pretty new stillany thoughts? Stupid third question, but does the ON tripper say ON? Trippers are not installed properly Re-install trippers on dial 2. Simple Ways to Set a Pool Timer: 11 Steps (with Pictures) - wikiHow My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. With this model can I control both of these motors with two different on and off times. So, the off dog just slips across the switch and doesnt allow the switch to turn off the motor. Put a meter on the wires or trace them back to find out their voltage and source. However, after several hours, maybe overnight, the associated breaker will trip. 1-48 of 242 results for "pool timer trippers" RESULTS. Phil. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. Now it worksbut its really fast. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. If I manually flip the switch nothing happens. "height": "219",
Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. Voltage is 243, frequency is 60hz. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! It stays on until I turn off the circuit breaker. Your email address will not be published. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. It could be a worn switch and/or tripper on the timeclock, struggling to switch it to on, which creates enough overload to trip the breaker. First, verify the power is turned off at the breaker panel. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. The problem is the 'off' tripper. I would suggest calling Intermatic and suggesting that idea and a free replacement? 220V clocks have 5 terminals, 110V clocks have 3 terminals. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. When you flip the switch does it separate and reconnect the tabs? Hi Davy, HELP! Tork timer not keeping time | Mike Holt's Forum It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. Timer not tripping pump on. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Thank you, I dont know about the box, was just told the mechanical timer a T104 is needed. It is a mechanical issue between the trippers and the switch lever. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! For extra safety, shut-off the Pool breaker on the main home panel too. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. More. The clock will also be missing 3-hours of time, so will need to be reset to the current time. Slide it around the pool timer dial to the correct start time and re-tighten it. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. I dont see any debris blocking the off dog. Are the gears engaged, in the center, behind the dial? Recently i just notice my T104R timer a bit noisier than usual. Push the tab on the top, and let the mechanism fall forward. Grab it, pull it towards you, move it around then place it back down. Any thoughts before I run out to replace it? Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. Date Listed: 18/02/2023; . Any ideas? Any suggestions? It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. The trippers push on a tab on the on/off switch. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Turn the metal bar until it contacts one of two plastic side tabs. Karl, good question. Yes, seen that before! Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. It sounds like the Line and Load wires are reversed. Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveler reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. The pool was running on a timer. Hi there, Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. I currently manually turn it on and off. Is this broken? The pool timers I have had down there . Gently tighten the screws to securely hold the dogs in place. It should sit down nicely. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Pool Timer Clock Parts and Trippers Or one of the wires may have broken, or lost the protective plastic insulation. Thanks again for your help. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . The terminals on the wires aren't tight. Check that the motor gears are still moving also, when it gets to the switch and the dial stops moving. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. At some time the timer was disconnected and the pump wired direct to the breakers. This page is fantastic!! Replace a new T104. I manually turn it on timer is running, it will trip pump OFF. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. 975 Telegraph Rd #103, Santa Paula, CA 93060 | MLS# V1-15365 | Redfin Pool co says T104 timer needs replacement and filter cartridge. Breakers go bad sometimes, after many years. Off flipper always works. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Help! i would like to use a timer but am now afraid to try another. You can manually engage it by turning it and then it will run and even SHUT OFF when its supposed to. Leave the paper inside your timer box so that you do not mistakenly misplace it. Hi, then the power for the clock must be from the switch, and not from the breaker? Hey there! Lately, the timer mechanism on my old T104R does not move. Clock wont move, gear dont move at all. Turn in either direction and align the exact time-of-day on . I have the Intermatic T103 autotimer on my pool. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. OPEN TODAY, 12PM TO 3PM. And does the switch look worn, where the tripper engages? Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. Please let me know if you find the solution! With the breakers turned off, remove the mechanism from the box. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. VIDEO TOUR. The freeze protection on your clock, the probe may be bad or malfunctioning, and may be turning off the pump. 110V or 220V? The 10 Best Pool Timers - Pool Care Guy Manual switch works my aerator. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Motor runs past the on dog but doesnt flip pump on? My pool timer is in the off position and it is still running. Black goes to _1 A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. This is the first step to confirm if there is power or not. AJH Trade Group is a participant in the Amazon Services LLC Associates Program. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. And when switched on, power to the load terminals? Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. Followed all directions and even watched YouTube troubleshooting videos. It should loosen up after a few goes when the grease and gunt dissolve. If you pull out on the clock dial, you can turn it to set the current time, aligning with the silver down-arrow, located at 6 oclock. Ordered new ones. If not, that sounds like a weak/bad motor. I had the exact same thing happen recently. #9. Turn the manual on/off switch. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. "width": "611",
Articles and resources for swimming pool owners and DIYers. When the power goes out, the timer stops. sometimes Im forgetful lol what are your thoughts? Clean the gears with a toothbrush if you see debris or gunk in them. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) PF1202T Freeze Protection Control Parts - INYOPools.com "identifier": ""
This product is certified by Amazon to work with Alexa. Go for it, a little maintenance expense. I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Why it always stop around 10pm by itself and not moving again? Make sure the middle time pointer is tight. "height": "219",
So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. During this the pump cannot be manually switched on. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Intermatic t101 timer troubleshooting - Ask Me Help Desk Intermatic Pool Timer Troubleshooting - In The Swim Pool Blog You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Thanks for any help you can give. I noticed that they had stopped. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi, PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control We cover T101, T103 and T104 models of mechanical pool timers. The trippers can also get damaged. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Hello have a question some what related. Wont work manually or by timer function. Hi, Davy, seeing lots of complaints here. I also dont see any ants or other insects. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Take them off and inspect them. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. When I put the new one on, the trippers do not work. Give it a little squirt of WD-40 or similar lubricant. If its loose, grab a screwdriver and tighten it up. Timer must be reset for current time after power outage. Turn the power off at the breaker box and carefully remove the wires to the clock. As an Amazon Associate we earn from qualifying purchases. You can turn off Freeze protection and it should stop, or replace the probe if faulty. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. . Switch the breaker off at the power board.
I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. How can it keep time if lever is in off position (manual lever). So out comes the soldering gun and the shrink wraps and that did the trick. 'Why not Toowoomba?': Tourism body says water park a missed opportunity Repeat the process for the "on" pin. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. Hello. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. You need extreme care in this next step. My time clock has an ant infestation! If it doesnt improve, inspect the contacts behind the time clock for insect infestation. Pools are not cheap! See the next section in this article for that. A timer that switches on and off at the wrong times usually occurs after a power outage. Basically youre eliminating possibilities until you find the cause. My original timer worked for 5 years then the clock stopped and I heard no sound. Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. "dateModified": "1/10/2020",
Perhaps bad wiring or a bad breaker is to blame. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. Death By Audio / Levitation Speed Tripper Feedback Phasing Delay Look for any disconnected or damaged wires leading to the motor on the rear of the clock. I notice my pool pump was not on so I went and I hear timer running but no juice to the pool filter. Is the timer repairable, or should I just install a new one? I called Intermatic and there is nothing you can do except check it every time you have a power loss. Donna Simpson Eating Website But What Toilet? There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! how do I check the manual over ride switch to see if it is off? i have a P1121 intermatic timer connected to a hayward above ground pool pump. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. Look into the visual motor check window, near the top of the timer mechanism.