Post Disclaimer
The information contained in this post is for general information purposes only. The information is provided by jandy aquapure control center and while we endeavour to keep the information up to date and correct, we make no representations or warranties of any kind, express or implied, about the completeness, accuracy, reliability, suitability or availability with respect to the website or the information, products, services, or related graphics contained on the post for any purpose.
Winterize your pool. The cartridge must be replaced. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. When I check the water temperature on my Aqualink Control Center by quickly pressing the Pool Temp Boost button, it shows 85 degrees which I believe is correct. The cell cannot be repaired even though the plates may have life left in them. You use the% generation control to adjust the actual amount of chlorine generated to meet your pools chlorine need. Check that ribbon cable is fully inserted into connector. A letter will be included with each new Tri-Sensor ALERTING Installers about the new installation instructions. Jandy AquaPure Power Center APUREM Controller | PoolSupply4Less Do I have to add salt every month with a salt water chlorinator? 2023 Zodiac Pool Systems LLC - All rights reserved. 21. Jandy AquaPure Control Center Parts |6 parts Frequently Purchased AquaPure Sanitizer Bottom Control Box Decal - R0404400 6 in stock $65.70 Add To Cart AquaPure Transformer - 115/230 Volts - R0481400 12 in stock $434.61 Add To Cart Control Box Cover, Pure1400 - R0403200 Allow 7-10 Days to Ship $185.91 Add To Cart Pure700 Control Box Cover - R0403100 Our heavy-duty AquaPure salt chlorine generators have been the industry benchmark for years. Backwash or partially drain pool and dilute with fresh water until salinity returns to 3.0 gpl to 3.5 gpl. Measures 6-inch diameter by 14-inch width by 9-1/2-inch height. Is it true that salt water chlorination is maintenance free? If the readings are correct then the board is O.K. Turn on pump. Haha! Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 . The PureLink DC Cord is Jandy P/N R0402800. That picture was after Snowmageddon. Manufacturer SKU: 6967+. However, if you have any doubts, do not try this!!! Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. Sign up now. Please consider. Work the first time without any issue or abnormal event. I chose the Zodiac PLC1400 to pair with it. [14] After discussions with a Jandy representative it was determined the problem was a bad board. Or just the control box? My pool is currently treated using bromide. Check that unit is correctly wired for 240 VAC and connected to 240 VAC. For very hard water, some chlorinators can shorten the polarity inversion time (e.g. Looks like your current store isn't near your delivery area. JavaScript is disabled. The center prong is the most common point of failure. Perks can be redeemed online, in store or in the Leslies app. Do Not Sell or Share My Personal Information. Had to down load from another site. Porto Seguro Cultural Center / Yuri Vital | ArchDaily Broadcast or spread the salt into the outer perimeter of the pool, or into the shallow end of the pool for quick and even distribution. If the Aquapure is disconnected from the Aqualink, then you should be able to set chlorine production from the front panel on the Aquapure. Jandy Aquapure Control Center | eBay 2023 Leslies Poolmart Inc. Were sorry we missed you; we look forward to assisting you soon. Natural stone can be visually altered over time. Jandy AquaPure Power Supply - APUREM - INYOPools.com That can be from low salt, low water temperature, a bad power cord, cell plates corroded or loose power pins. Check connector at white plug to insure proper connection. It's usually cheaper to buy the Aquapure 1400 cell kit that comes with the cell, trisensor and power cord vs. buying the parts separately. Add To Cart. Verify salinity with Myron L meter calibrated for NaCl, titration test units, or other salt meters. Check for correct operation of the pump. While still pressing the test buttons press the Salinity key (C) on the front cover of the unit. If still too low, Super Chlorinate with outside source. Q: Tri-Sensor R-kits will ship first, beginning with date code 10/6/14. A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. Ensure there is no loss of pump prime or clogged strainer baskets. Jandy APUREM AquaPure Salt Generator Power Center, Brand new returned unit - Never installed just opened, Create a Saltwater Oasis in Your Backyard, Automatic self-cleaning feature ensures consistent operation and extended lifespan of the cell, Exclusive Tri-Sensor technology provides reliable electronic water flow detection to sustain maximum performance, even at very low flow rates, Digital salinity read-out for accurate salt-level indication, Flow, temperature and status readings provide instant feedback on the current operation, When combined with PureLink power centers, AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience, Seamless communication with AquaLink Control systems enables easy monitoring of salt levels and convenient, precise sanitizer output settings, Note: The salt cells are sold separately The Flow & Salinity Sensor is Jandy P/N R0452500. You can check the calibration by doing the following below procedure. This is related to the serial com connections that are used. Changes to Aquapure settings made on Aqualink will not show on the Aquapure and the chlorine% will be 0. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. Jandy AquaPure control center for Jandy AquaPure PLC1400 and PLC700 chlorine generator cells. Sorry - Air temperature sensor. Select Options. Do Not use Rock salt (insoluble impurities mixed with the rock salt can shorten the life of the unit). This method would require the purchase of 4 unions. PDF WARNING - INYOPools.com Note: The salinity or salt level should always be tested before salt is added to the pool. Decrease the chlorine production rate adjustment button (arrow button A). AquaPure Salt Water Pool System - Jandy You can sometimes fix it by cleaning off the corrosion.[10]. For urgent questions, you can reach us directly at The purer the salt, the better the life and performance of the electrolytic cell. Brief content visible, double tap to read full content. The system then reuses the salt and the process starts over again. Different Water Temperature Readings on Jandy Aquapure Control Center Report PoolGate Gold Supporter TFP Guide Jun 7, 2017 7,748 Damascus, MD Pool Size 29000 You are using an out of date browser. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. Pool guy installed quickly and it is working great. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. ORP / External Control Interface 2. Includes: 1 - Power Interface Board Assembly. After 24 hours, verify correct salt reading. Jandy AquaPure SWG - Further Reading | Trouble Free Pool I chose the Zodiac PLC1400 to pair with it. See Section 4.5 of the owner's manual. Press and hold the test buttons marked salinity and R-temp. 20 points earns $1 Pool Perks reward. Please try again. Reviewed in the United States on September 23, 2016, Reviewed in the United States on February 1, 2015, Reviewed in the United States on April 28, 2014. Filter, Hayward Star-Clear Cartridges C-250 thru C-1750, Hayward Swim Clear Large Capacity Cartridges, Pentair Purex Bottom Manifold Filter Grids, Pentair Replacement Cartridges QUAD Filters, Filter Backwash Valves, Diverter Valves, Check Valves, Hayward Navigator - PoolVac Cleaner Parts, Pool Control Systems and Automation Parts, Aquarite Cell Replacements - Above Ground, Hayward Aquarite Goldline Parts, Sensors, Boards, Jandy Zodiac Salt Cell PLC1400 Aquapure1400 PureLink Cell Kit 40K, Jandy PLC700 PureLink 7-Blade Salt Generator Cell Kit, Hayward Salt & Swim 3C Control Unit Only W3SAS-PRO, Hayward Salt & Swim 3C Replacement Salt Cell W3SAS-CELL, Pentair IntelliChlor Salt Generator Above Ground Pools IC15 EC-520888, SmartSalt Salt Chlorine Generator 25K 25,000 Gallons, Hayward AquaTrol RJ Salt Chlorine Generator W3AQ-TROL-RJ, Pentair Intellichlor IC60 Salt Water System 521105 and 520556. There are numerous sites that have detailed information about the install. A separate communication will follow . Free Shipping and more for Pool Perks members. $200 later guy said unit was shipped without a translatetor card???? Free shipping for many products! In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved. Make sure that temp is above 60, salt is 3400, power cord is good and look in the cell at the plates with a good light from both ends to see if the plates are corroded. Use a salt that is at least 99.8% pure NaCl. An optional "Spool" Piece (sold separately) used to be available to replace the cell during winterizing or cell maintenance. If there is still a large amount of bromide in your pool, we recommend that you wait for it to dissipate. PDF Jandy Aqua Pure View More Details. New, not old stock, in sealed box. Sorry, we were unable to perform your search at this time. See pages 13-14 in Jandy AquaPure Troubleshooting. Quantity. First thing to check is the cord. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. The AquaPure control center converts AC power into low voltage DC current which is required by the cell to perform the electrolysis. AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual, AquaPure and PureLink Tri-Sensor Replacement Kits. Jandy switched to a 3-port cell design to aid in cleaning and plumbing flexibility and no longer makes 2-port cells. Power Center Compatible with Pentair IntelliChlor Pool, APPLIAFIT O-Ring Compatible with Jandy Zodiac R0357800 for CL, CV, DEL & DEV Series Filters (2-Pack), Tier1 Pool & Spa Filter Cartridge | Replacement for Dimension One 1561-00, Pleatco PDO75-2000, FC-3059, C-7367, Aladdin 17541 and More | 75 sq ft Pleated Fabric Filter Media, POOLPURE PDM28 Spa Filter Replaces Aquarest Dream Maker 461273 Hot Tub Filter, 2 Pack, SpaO2 Swimming Pool Aerators - Set of 2, ABS Injection Molding, Fit 1-1/2 FIP/MIP Threaded Return outlets, MAX Depth 19.7, Raise pH Without Changing Alkalinity, Crystal Clear Water, Less Chemicals, 1996-2023, Amazon.com, Inc. or its affiliates, Zodiac APUREM AquaPure Foundation Power Center Pack Replacement for Zodiac Jandy AquaPure PureLink Cell Kit. See Section 6.4 of the owner's manual. Register product at Jandy.com/registration. Plug flow/temp/salinity sensor into connector on power center printed circuit board. You must log in or register to reply here. It was a bad water temperature sensor. The three pins go inside and connect to the plates. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE. After installing began to flash code of 181 & 172.